Method Description Sheet

Method EPA Method 609
Title Nitroaromatics and Isophorone
Abstract A measured volume of sample, approximately one-liter, is extracted with methylene chloride using separatory funnel techniques. The extract is dried and exchanged to hexane during concentration to 1.0 mL by evaporation. Isophorone and nitrobenzene are measured by flame ionization gas chromatography (FIDGC). The dinitrotoluenes are measured by electron capture GC (ECGC).

Compounds Analyzed :

Selecting a CAS number from the table below will direct you to the
National Library of Medicine's Hazardous Substances Database for more details on the compound.

CAS #Compound Name
121-14-22,4-Dinitrotoluene
606-20-22,6-Dinitrotoluene
78-59-1 Isophorone
98-95-3Nitrobenzene